| 注册
首页|期刊导航|肉类研究|微波消解-电感耦合等离子体质谱法同时测定肉及肉制品中7种痕量元素

微波消解-电感耦合等离子体质谱法同时测定肉及肉制品中7种痕量元素

吴春敏 夏静 李强 张岩

肉类研究Issue(3):27-29,3.
肉类研究Issue(3):27-29,3.DOI:10.7506/rlyj1001-8123-201503007

微波消解-电感耦合等离子体质谱法同时测定肉及肉制品中7种痕量元素

Simultaneous Determination of 7 Trace Elements in Meat and Meat Products by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) with Microwave Digestion

吴春敏 1夏静 1李强 1张岩1

作者信息

  • 1. 河北省食品检验研究院,河北省食品安全重点实验室,河北石家庄 050091
  • 折叠

摘要

Abstract

A method for the simultaneous determination of 7 trace elements (lead, arsenic, cadmium, chromium, selenium, mercury, and nickel) in meat and meat products by inductively coupled plasma mass spectrometry (ICP-MS) with microwave digestion was established. Samples were pretreated by microwave digestion and determined by ICP-MS with rhodium (Rh) as the internal standard. The microwave digestion conditions and the instrumental parameters were optimized. It was found that the instrumental signal drift and matrix effect could be overcome by using the internal standard method. The developed standard curve was linear in the range of 0 to 20 ng/mL, with a correlation coefficient of more than 0.999. The recoveries of the analytes in spiked samples ranged from 89.4% to 98.9% and the precision expressed as relative standard deviation was less than 5%. The limits of detection for the trace elements were all lower than those stipulated in the Chinese national standards. The proposed method was rapid, accurate, reliable, sensitive and suitable for simultaneous multi-element analysis of meat and meat products.

关键词

微波消解/电感耦合等离子体质谱/肉及肉制品/重金属

Key words

microwave digestion/inductively coupled plasma mass spectrometry (ICP-MS)/meat and meat products/heavy metal

分类

轻工纺织

引用本文复制引用

吴春敏,夏静,李强,张岩..微波消解-电感耦合等离子体质谱法同时测定肉及肉制品中7种痕量元素[J].肉类研究,2015,(3):27-29,3.

肉类研究

OA北大核心

1001-8123

访问量0
|
下载量0
段落导航相关论文