食品与机械2016,Vol.32Issue(11):71-73,3.DOI:10.13652/j.issn.1003-5788.2016.11.016
冷凝温度变化对两相射流泵供液平板速冻机的影响
The effects of condensing temperature changes on plate freezer with two-phase ejector
摘要
Abstract
The working performance of plate freezer with two-phase e-jector in different condensing temperature was investigated in this study.Moreover,the effects of condensing temperature on freezing rate and total energy consumption of plate freezer was also studied. Then the entrainment coefficient in stable conditions and explores the effects on Jet pumps were analyzed by changing the condensing tem-perature.The results showed that when the condensing temperature was 25 ℃,the ejecting coefficient was the highest about 1 .58.Com-pared with 40 ℃and 30 ℃,the energy consumption was lowered by about 3.3% and 10% at 25 ℃,and the freezing time was shorten by about 12.5% and 1 7.5%,respectively.关键词
平板速冻机/食品冷冻/冷凝温度/射流泵/冻结速率/能耗Key words
plate freezer/frozen food/condensingtemperature/ejector/freezing-rate/energyconsumption引用本文复制引用
田晓雨,万金庆,曹晓程,厉建国..冷凝温度变化对两相射流泵供液平板速冻机的影响[J].食品与机械,2016,32(11):71-73,3.基金项目
国家高技术研究发展计划(编号:2012AA092301) (编号:2012AA092301)