摘要

Abstract

The method of measuring rice protein with fully automatic Kieldahl azotometer by single-factor experiment and orthogonal experiment was investigated.It defines the best experiment conditions through examining such key factors as sample weight,additive a mount of sulfuric acid,digesting temperature and digesting time.The results showed that when the sample weight is 0.40 g,the added amount of sulfuric acid was 12 mL,digested at is 420 ℃ and for 50 min,the experimental effect was the best.The standard deviations of 6 determinations of 5 kinds of rice were 0.050 2~0.101 1,and the recoveries of nitrogen of urea were 99.9% ~ 100.5%.The ratios of protein obtained by semi-micro distillation method were between 1.023 4~1.079 4,and the time of determination could be shortened to 1 hours.The method was found stable and accurate.

关键词

蛋白质/全自动凯氏定氮仪/样品质量/硫酸添加量/消化温度/消化时间

Key words

protein/automatic kjeldahl apparatus/sample weight/concentrated sulfuric acid/digestion temperature/digestion time