| 注册
首页|期刊导航|轻工学报|基于HCPS多层感知器的污水处理后氨氮浓度测量

基于HCPS多层感知器的污水处理后氨氮浓度测量

高明 崔钶 李昊 栗三一

轻工学报2018,Vol.33Issue(6):92-100,108,10.
轻工学报2018,Vol.33Issue(6):92-100,108,10.DOI:10.3969/j.issn.2096-1553.2018.06.011

基于HCPS多层感知器的污水处理后氨氮浓度测量

Measurement of ammonia nitrogen concentration after sewage treatment based on HCPS multilayer perceptrons

高明 1崔钶 1李昊 1栗三一2

作者信息

  • 1. 黄河流域水环境监测中心 监测管理处,河南 郑州 450004
  • 2. 郑州轻工业学院 电气信息工程学院,河南 郑州 450001
  • 折叠

摘要

Abstract

In the existing prediction model of ammonia nitrogen in sewage treatment effluent, the hidden layer neurons excessively redundant, which wastes resources. A new structure adjustment algorithm( HCPS) based on sensitivity analysis( SA) and mutual information( MI) was proposed. The algorithm redefined the sensitivity formula, adaptively, adjusted the network structure by using sensitivity and mutual information, deleted hidden neurons with low sensitivity, divided hidden neurons with excessive sensitivity, and merged two hidden neurons with excessive mutual information. The results of verification on BSM1, a benchmark simulation platform for sewage treatment, showed that HCPS algorithm could obtain a more compact network structure, and the prediction accuracy of ammonia nitrogen concentration in effluent was higher.

关键词

污水处理/氨氮浓度预测/软测量技术/神经网络结构自调整算法/多层感知器/结构自组织

Key words

sewage treatment/ammonia nitrogen concentration prediction/soft measurement/HCPS/multilayer perceptron/structural self-organizing

分类

信息技术与安全科学

引用本文复制引用

高明,崔钶,李昊,栗三一..基于HCPS多层感知器的污水处理后氨氮浓度测量[J].轻工学报,2018,33(6):92-100,108,10.

基金项目

国家自然科学基金项目(61603347) (61603347)