| 注册
首页|期刊导航|现代食品科技|高盐食品基质中砷含量的测定

高盐食品基质中砷含量的测定

戴瑞平 刘花梅 舒露 唐丽君 黎申英 李彪 张梅玲 刘涛 黄宗兰

现代食品科技2024,Vol.40Issue(4):321-330,10.
现代食品科技2024,Vol.40Issue(4):321-330,10.DOI:10.13982/j.mfst.1673-9078.2024.4.0479

高盐食品基质中砷含量的测定

Determination of Arsenic Content in High-salt Food Matrices

戴瑞平 1刘花梅 1舒露 2唐丽君 1黎申英 1李彪 1张梅玲 1刘涛 1黄宗兰1

作者信息

  • 1. 江西省检验检测认证总院食品检验检测研究院,江西南昌 330052
  • 2. 江西省检验检测认证总院检测认证技术发展研究院,江西南昌 330029
  • 折叠

摘要

Abstract

A matrix matching-dynamic reaction cell-inductively coupled plasma mass spectrometry method for determining the arsenic content in high-salt food matrices was established,to solve the mass spectrum interference and matrix interference of a high-salt matrix on arsenic determination.The key technical points for the determination of total arsenic in foods by inductively coupled plasma mass spectrometry and hydride generation atomic fluorescence spectrometry were investigated.A method for determining the arsenic in high-salt food matrices was established through analyzing the effects of pretreatment and digestion methods,organic matrix,chlorine content and internal standard correction elements on the determination of arsenic content.The experimental results show that the microwave digestion method is not quite suitable for the determination of total arsenic in food by hydride generation atomic fluorescence spectrometry.The organic matrix and chlorine will produce a sensitizing effect and mass spectral interference on the mass spectrometry signal of arsenic,respectively.74Ge is more suitable than 72Ge as an internal standard element for the determination of total arsenic in food by inductively coupled plasma mass spectrometry.LOQ of the established method was 0.010 mg/kg,recovery rate of arsenic in high-salt matrices was 91.50%~110.80%when the addition level was 0.010,0.025,0.20 or 0.50 mg/kg,and the relative standard deviation range was 0.76%~7.22%.The statistical values of the sample analysis results obtained by this method and the reference method were both higher than t0.90,10(1.81,bilateral),and there is a significant difference in the determination results.The measurement results of actual samples revealed that the kinetic energy discrimination measurement model is not suitable for the determination of total arsenic in high-salt food matrix samples.The method is accurate and reliable,and can be applied for the determination of arsenic content in high salt-and high-matrix foods.

关键词

高盐食品基质/氢化物发生原子荧光光谱法/电感耦合等离子体质谱法/基体匹配

Key words

high salt food matrix/hydride generation atomic fluorescence spectrometry/inductively coupled plasma mass spectrometry/matrix matching

引用本文复制引用

戴瑞平,刘花梅,舒露,唐丽君,黎申英,李彪,张梅玲,刘涛,黄宗兰..高盐食品基质中砷含量的测定[J].现代食品科技,2024,40(4):321-330,10.

基金项目

江西省市场监督管理局科技项目(GSJK202208) (GSJK202208)

现代食品科技

OA北大核心CSTPCD

1673-9078

访问量4
|
下载量0
段落导航相关论文