文章针对凝冻积冰环境下风电机组叶片气热法防除冰技术展开现场试验,验证其防除冰效果及加热能耗.首先,分析了叶片表面结冰复杂过程并模拟计算NACA64618翼型表面积冰分布;然后,结合2MW风电机组构建叶片主动气热法防除冰系统并实施现场示范工程;最后,开展了风电机组叶片静态除冰试验、防冰试验及防冰生产运行试验,辅助全景红外热成像检测分析叶片防除冰效果及加热能耗.试验结果表明,在冰厚为30 mm并控制加热温度为 50℃的前提下,持续加热 2h后叶片表面开始融冰脱落,加热能耗功率不足 50 kW.可为风电机组叶片气热法防除冰的工程应用系统设计提供参考.

In freezing and icing environment,the field tests of 2 MW wind turbine blades by aerothermal anti-icing/de-icing method is carried out to verify the anti-icing/de-icing effect and energy consumption.Firstly,this paper analyzes the complex process of blade surface icing and then its icing distribution on the surface of NACA64618 airfoil is simulated.Secondly,the blade active aerothermal anti-icing/de-icing system for 2 MW wind turbine is constructed in the field demonstration project.Finally,three tests are finished with the help of the panoramic infrared thermal imaging detection,including the static de-icing test,static anti-icing test and production test with anti-icing,and then evaluate blade anti-icing/de-icing effect and heating energy consumption.The test results show that the blade surface begins to melt and fall off after continuous heating for 2 hours when the ice thickness is 30 mm and the heating control temperature is 50℃,and the heating energy consumption power is less than 50 kW,which can provide a reference for the design of engineering application system of aerothermal anti-icing and de-icing of wind turbine blade.

李伟;李志刚;李显树;张奎;邹志波;周志宏

贵州能源产业研究院有限公司,贵州 贵阳 550025大唐贵州新能源开发有限公司,贵州 贵阳 556000四川大学 建筑与环境学院,四川 成都 621000

能源与动力

风电机组叶片结冰气热法防除冰现场试验融冰脱冰加热能耗

wind turbineblade icingaero-thermal anti-icing/de-icingfield testmelt and fallheating energy consumption

《可再生能源》 2024 (005)

634-639 / 6

贵州省省级科技计划项目(黔科合成果[2024]一般142,黔科合支撑[2019]2035);国家自然科学基金项目(12072213).