为提升污水系统弹性和韧性,文章分析了郑州市污水系统存在的问题,提出了郑州市污水厂群应急联合调度布局.这种布局能有效应对污水厂应急污水出路问题,提升运行安全保障,同时最重要的是通过跨区域调配实现了未饱和污水厂和超负荷污水之间的有效调度,使郑州市各污水厂高效节能运行.联合调度是未来城市污水系统运营模式的发展趋势,有利于城市的可持续发展,通过实施了郑州市污水厂群应急联合调度,为平原地区污水互联互通建设提供了切合可行的实例.

In order to improve the elasticity and toughness of the wastewater system,this paper analyzed the existing problems of the wastewater system in Zhengzhou City,and put forward the emergency joint dispatching layout of the wastewater treatmnt plant(WWTP)group in Zhengzhou City.This layout can not only effectively cope with the emergency sewage outlet of the WWTP,improve the operation safety guarantee,but also,most importantly,realize the effective scheduling between the unsaturated WWTP and the overloaded wastewater through cross-regional deployment,so that the WWTPs in Zhengzhou City can operate efficiently and energy-saving.Joint dispatching is the future development trend of urban wastewater system operation mode,which is conducive to the sustainable development of the city.Through the implementation of the emergency joint dispatching of Zhengzhou WWTP group,it provides a feasible example for the construction of wastewater interconnection in plain area.