|国家科技期刊平台
首页|期刊导航|烟草科技|基于微焦点CT的烟支内部孔隙率检测

基于微焦点CT的烟支内部孔隙率检测OA北大核心CSTPCD

Detection of tobacco rod porosity inside a cigarette using microfocus computerized tomography

中文摘要英文摘要

为了研究烟支内部孔隙分布情况,同时解决烟支内部烟丝填充状态测量方法的不足,利用微焦点X射线CT成像技术对烟支进行三维扫描,对获取的透射信息进行处理,得到烟支二维截面图像堆栈和三维重建模型,建立了烟支不同截面、扇段和圆环柱内部孔隙率分析表征方法.对常规卷烟、中支卷烟、细支卷烟和加热卷烟的CT扫描结果进行分析,得出以下结论:①烟支轴向不同截面孔隙率分析结果显示,传统卷烟孔隙率变化趋势基本相同,即轴向中间部分在平均孔隙率附近波动,向两端的过程中出现了孔隙率先变小再变大的趋势;而加热卷烟中间部分孔隙率均匀波动,两端孔隙率直接变大.②各种类烟支不同扇段孔隙率变化趋势相同,均呈现先下降后上升再下降的趋势.③除了常规卷烟中2.5~3.0 mm圆环柱的孔隙率突然增大之外,其他3种烟支中不同圆环柱的孔隙率变化趋势相同,均呈现先上升再下降后上升的趋势.

In order to study the internal pore distribution of a cigarette and to address some of the shortcomings of the current measurement methods for cut tobacco filling state in cigarettes,three-dimensional scanning was performed by using microfocus X-ray computerized tomography(CT)imaging technology,and the obtained structural information was processed to develop both two-dimensional cross-sectional image stacks and three-dimensional reconstruction model of a cigarette.The analysis and characterization methods for the internal porosities of different cross-sections,fan-shaped segments and circular columns of cigarettes were established.The CT scanning results of unlit king-sized,demi-slim,slim cigarettes and heated tobacco rods were analyzed.The results showed that:1)The porosities of different cross-sections indicated that the axial changes of conventional,demi-slim and slim cigarettes were basically the same,namely the porosities of the middle sections fluctuated around the average porosities,and those of both ends first decreased and then increased.However,the porosities of the middle sections of the heated tobacco product fluctuated uniformly,and those of both ends increased directly.2)The porosities of different segments of traditional cigarettes and heated tobacco products had the same change trend,namely first decreased,then increased and then decreased.3)Except for the marked increase in the porosity of the 2.5-3.0 mm circular columns in the conventional cigarettes,the porosities of the different circular columns of the demi-slim and slim cigarettes and the heated tobacco rods showed a similar trend,namely first increased,then decreased,and then increased.

赵鑫;张越;邓国栋;刘朝贤;朱文魁;王乐;张柯;李欢;许璐;张军;张齐

中国烟草总公司郑州烟草研究院,郑州高新技术产业开发区枫杨街2号 450001广西中烟工业有限责任公司柳州卷烟厂,广西壮族自治区柳州市城中区静兰路1号 545001重庆中烟工业有限责任公司,重庆市涪陵区鹤凤大道16号 408000江西中烟工业有限责任公司,南昌市青山湖区高新开发区京东大道201号 330046

轻工业

微焦点CT三维重建内部孔隙率检测

Microfocus CTThree-dimensional reconstructionPorosity detection

《烟草科技》 2024 (005)

75-82 / 8

烟草行业烟草工艺重点实验室引领计划专项科技项目"烟支三维结构检测和数字化表征技术研究"(202022AWCX01).

评论