|国家科技期刊平台
首页|期刊导航|Chinese Medical Journal|Development of a radiomics model to discriminate ammonium urate stones from uric acid stones in vivo:A remedy for the diagnostic pitfall of dual-energy computed tomography

Development of a radiomics model to discriminate ammonium urate stones from uric acid stones in vivo:A remedy for the diagnostic pitfall of dual-energy computed tomographyOACSTPCDMEDLINE

中文摘要

Background:Dual-energy computed tomography(DECT)is purported to accurately distinguish uric acid stones from non-uric acid stones.However,whether DECT can accurately discriminate ammonium urate stones from uric acid stones remains unknown.Therefore,we aimed to explore whether they can be accurately identified by DECT and to develop a radiomics model to assist in distinguishing them.Methods:This research included two steps.For the first purpose to evaluate the accuracy of DECT in the diagnosis of uric acid stones,178 urolithiasis patients who underwent preoperative DECT between September 2016 and December 2019 were enrolled.For model construction,93,40,and 109 eligible urolithiasis patients treated between February 2013 and October 2022 were assigned to the training,internal validation,and external validation sets,respectively.Radiomics features were extracted from non-contrast CT images,and the least absolute shrinkage and selection operator(LASSO)algorithm was used to develop a radiomics signature.Then,a radiomics model incorporating the radiomics signature and clinical predictors was constructed.The performance of the model(discrimination,calibration,and clinical usefulness)was evaluated.Results:When patients with ammonium urate stones were included in the analysis,the accuracy of DECT in the diagnosis of uric acid stones was significantly decreased.Sixty-two percent of ammonium urate stones were mistakenly diagnosed as uric acid stones by DECT.A radiomics model incorporating the radiomics signature,urine pH value,and urine white blood cell count was constructed.The model achieved good calibration and discrimination{area under the receiver operating characteristic curve(AUC;95%confidence interval[CI]),0.944(0.899-0.989)},which was internally and externally validated with AUCs of 0.895(95%CI,0.796-0.995)and 0.870(95%CI,0.769-0.972),respectively.Decision curve analysis revealed the clinical usefulness of the model.Conclusions:DECT cannot accurately differentiate ammonium urate stones from uric acid stones.Our proposed radiomics model can serve as a complementary diagnostic tool for distinguishing them in vivo.

Junjiong Zheng;Jie Zhang;Jinhua Cai;Yuhui Yao;Sihong Lu;Zhuo Wu;Zhaoxi Cai;Aierken Tuerxun;Jesur Batur;Jian Huang;Jianqiu Kong;Tianxin Lin;

Department of Urology,Sun Yat-Sen Memorial Hospital,Sun Yat-Sen University,Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation,Guangdong Provincial Clinical Research Center for Urological Diseases,Guangzhou,Guangdong 510120,ChinaDepartment of Neurology,Sun Yat-Sen Memorial Hospital,Sun Yat-Sen University,Guangzhou,Guangdong 510120,ChinaDepartment of Radiology,Sun Yat-Sen Memorial Hospital,Sun Yat-Sen University,Guangzhou,Guangdong 510120,ChinaDepartment of Urology,The First People’s Hospital of Kashgar Prefecture,Kashgar,Xinjiang 844000,China

临床医学

Ammonium urateDual-energy scanned projection radiographyRadiomicsUric acidUrolithiasis

《Chinese Medical Journal》 2024 (009)

P.1095-1104 / 10

supported by the China Postdoctoral Science Foundation(Nos.2021TQ0387,2022M713625,and 2021M703709);the National Natural Science Foundation of China(Nos.82203188 and 81825016);Guangdong Provincial Clinical Research Center for Urological Diseases(No.2020B1111170006);the Guangdong Basic and Applied Basic Research Foundation(No.2020A1515111119)

10.1097/CM9.0000000000002866

评论