| 注册
首页|期刊导航|制冷学报|R290、R454C替代R404A在商用冰箱中的应用性能对比研究

R290、R454C替代R404A在商用冰箱中的应用性能对比研究

王泽斌 薛雯 李梦佳 田雅芬 张华 苏明宏

制冷学报2024,Vol.45Issue(4):36-42,7.
制冷学报2024,Vol.45Issue(4):36-42,7.DOI:10.3969/j.issn.0253-4339.2024.04.036

R290、R454C替代R404A在商用冰箱中的应用性能对比研究

Comparative Study on the Performance of R404A Commercial Refrigerator Retrofitted with R290 and R454C

王泽斌 1薛雯 1李梦佳 1田雅芬 1张华 1苏明宏2

作者信息

  • 1. 上海理工大学能源与动力工程学院 上海 200093
  • 2. 上海金城制冷设备有限公司 上海 201805
  • 折叠

摘要

Abstract

R404A is widely used in light commercial equipment.However,the Kigali Amendment currently specifies the refrigerant replacement process.R454C and R290,owing to their low global warming potential values,have become promising refrigerants for use in commercial refrigerators.To compare the performances of these three refrigerants in commercial refrigerators,this study uses a climatic chamber to test four commercial refrigerators of different sizes.Four key parameters,namely the refrigerant charge,energy consumption,material cost,and carbon emissions,of the R404A,R454C,and R290 systems were compared.The results indicated that replacing R404A with R454C resulted in energy savings of approximately 5%and a reduction of approximately 15%in carbon emissions.When using R290,the charge was only 20.6%-34.3%of that of R404A,remaining within a safe range.Additionally,the charging cost was only half that of R404A.Furthermore,the system satisfied the performance requirements with this charge amount,leading to a reduction in energy consumption and carbon emissions within the ranges of 15%-35%and 25.3%-43.7%,respectively.

关键词

R290/商用冰箱/制冷性能实验/碳排放量

Key words

R290/commercial refrigerator/refrigeration performance test/CO2 emission

分类

通用工业技术

引用本文复制引用

王泽斌,薛雯,李梦佳,田雅芬,张华,苏明宏..R290、R454C替代R404A在商用冰箱中的应用性能对比研究[J].制冷学报,2024,45(4):36-42,7.

基金项目

国家自然科学基金(52206016)资助项目.(The project was supported by the National Natural Science Foundation of China(No.52206016).) (52206016)