|国家科技期刊平台
首页|期刊导航|制冷学报|R290、R454C替代R404A在商用冰箱中的应用性能对比研究

R290、R454C替代R404A在商用冰箱中的应用性能对比研究OA北大核心CSTPCD

Comparative Study on the Performance of R404A Commercial Refrigerator Retrofitted with R290 and R454C

中文摘要英文摘要

R404A在轻商设备中应用广泛,目前《基加利修正案》中明确规定了制冷剂替代进程,R454C和R290由于GWP更低,成为商用冰箱中替代前景较好的制冷剂.为了对比这3种不同工质在商用冰箱中的应用性能,在焓差实验室中测试了 4款不同规格的小型商用冰箱,并对比了 R404A、R454C和R290系统的充注量、耗电量、材料成本与碳排放量等参数.研究结果表明:相比R404A系统,R454C系统24 h耗电量可降低约5%,总碳排放量减少约15%;替换为R290后,系统充注量大幅降低,仅为R404A的20.6%~34.3%,大幅降低了制冷剂充注成本,且24 h耗电量可降低约15%~30%,碳排放量降低25.3%~43.7%.

R404A is widely used in light commercial equipment.However,the Kigali Amendment currently specifies the refrigerant replacement process.R454C and R290,owing to their low global warming potential values,have become promising refrigerants for use in commercial refrigerators.To compare the performances of these three refrigerants in commercial refrigerators,this study uses a climatic chamber to test four commercial refrigerators of different sizes.Four key parameters,namely the refrigerant charge,energy consumption,material cost,and carbon emissions,of the R404A,R454C,and R290 systems were compared.The results indicated that replacing R404A with R454C resulted in energy savings of approximately 5%and a reduction of approximately 15%in carbon emissions.When using R290,the charge was only 20.6%-34.3%of that of R404A,remaining within a safe range.Additionally,the charging cost was only half that of R404A.Furthermore,the system satisfied the performance requirements with this charge amount,leading to a reduction in energy consumption and carbon emissions within the ranges of 15%-35%and 25.3%-43.7%,respectively.

王泽斌;薛雯;李梦佳;田雅芬;张华;苏明宏

上海理工大学能源与动力工程学院 上海 200093上海金城制冷设备有限公司 上海 201805

R290商用冰箱制冷性能实验碳排放量

R290commercial refrigeratorrefrigeration performance testCO2 emission

《制冷学报》 2024 (004)

36-42 / 7

国家自然科学基金(52206016)资助项目.(The project was supported by the National Natural Science Foundation of China(No.52206016).)

10.3969/j.issn.0253-4339.2024.04.036

评论