| 注册
首页|期刊导航|CT理论与应用研究|低管电流联合深度学习算法在副鼻窦CT成像中的对比研究

低管电流联合深度学习算法在副鼻窦CT成像中的对比研究

孙宇飞 钟朝辉 李向明 周万博 许晨思 邓淼 张立新

CT理论与应用研究2025,Vol.34Issue(3):351-358,8.
CT理论与应用研究2025,Vol.34Issue(3):351-358,8.DOI:10.15953/j.ctta.2024.288

低管电流联合深度学习算法在副鼻窦CT成像中的对比研究

Contrast Study of Low Tube Current Combined with Deep Learning Algorithms in Paranasal Sinus CT Imaging

孙宇飞 1钟朝辉 1李向明 1周万博 2许晨思 2邓淼 3张立新1

作者信息

  • 1. 首都医科大学附属北京友谊医院放射科,北京 100050
  • 2. 东软医疗系统股份有限公司,沈阳 110167
  • 3. 中国康复研究中心北京博爱医院放射科,北京 100068
  • 折叠

摘要

Abstract

Objective:To explore the application effect of a low tube current combined with a deep learning algorithm in paranasal sinus computed tomography(CT)imaging and to evaluate its advantages in terms of image quality and radiation dose.Methods:Patients who underwent paranasal sinus CT examinations at Beijing Friendship Hospital,Capital Medical University,between March and November 2024 were retrospectively collected and divided into three groups:conventional dose group,low tube current with deep clearInfinity(CI)group,and clearView(CV)group.The CT values,SD values,signal-to-noise ratios(SNR),and contrast-to-noise ratios(CNR)of the inferior turbinate mucosa,medial pterygoid muscle,and temporal fossa fat were measured and calculated for each group to objectively assess image quality.In addition,two head and neck radiologists subjectively scored the image quality of the thinnest slice on a 4-point scale.The radiation doses in the conventional and low tube current groups were also compared.Results:A total of 80 patients were included in this study,with 40 in each group.There were no statistically significant differences in the CT values among the three groups for the inferior turbinate mucosa,medial pterygoid muscle,and temporal fossa fat.There were no statistically significant differences in SD values,SNR,and CNR between the conventional-dose and CI groups.However,statistically significant differences were observed in SD values and SNR between the conventional and CV groups,as well as between the CI and CV groups for the inferior turbinate mucosa,medial pterygoid muscle,and temporal fossa fat.For CNR,statistically significant differences were also found between the conventional and CV groups and between the CI and CV groups in the inferior turbinate mucosa and medial pterygoid muscle regions.In terms of subjective image quality scores,the conventional and CI groups scored 3.93±0.26 and 3.88±0.33,respectively,which were significantly higher than the CV group's score of 2.70±0.46.Additionally,the radiation dose in the low tube current group was reduced by approximately 74.8%compared to that in the conventional group,with a statistically significant difference.Conclusion:Low tube current combined with a deep learning algorithmin paranasal sinus CT imaging can significantly reduce the radiation dose while maintaining image quality.

关键词

深度学习算法/迭代算法/副鼻窦CT/低剂量CT

Key words

deep learning algorithm/iterative algorithm/paranasal sinus CT/low-dose CT

分类

信息技术与安全科学

引用本文复制引用

孙宇飞,钟朝辉,李向明,周万博,许晨思,邓淼,张立新..低管电流联合深度学习算法在副鼻窦CT成像中的对比研究[J].CT理论与应用研究,2025,34(3):351-358,8.

CT理论与应用研究

1004-4140

访问量0
|
下载量0
段落导航相关论文