CT理论与应用研究2025,Vol.34Issue(3):385-391,7.DOI:10.15953/j.ctta.2024.210
足头向Flash扫描对下肢动脉CTA图像质量和辐射剂量的研究
A Study of Image Quality and Radiation Dose in Lower Extremity Computed Tomography Angiography Using Caudo-cranial Flash Scanning
戚荣飞 1姜文龙 1郝芸芸 1杨柳莎 1常英娟 1吴志斌1
作者信息
- 1. 空军军医大学第一附属医院放射科,西安 710032
- 折叠
摘要
Abstract
Objective:We conducted a comparative study of image quality and radiation dose in computed tomography angiography(CTA)of lower extremity arteries with single-source CT cranio-cauda and dual-source CT cranio-cauda Flash scans.Methods:This prospective study enrolled 50 patients with suspected peripheral occlusive arterial disease which required CTA imaging of the lower extremities.Patients were randomly assigned to a control group(P1)or an experimental group(P2).Group P1 was scanned with protocol 1:single-source CT cranio-cauda direction,Group P2 was scanned with protocol 2:dual-source CT cranio-cauda direction Flash.Intravascular CT values,signal-to-noise ratio(SNR),and contrast-to-noise ratio(CNR)were compared as a group.Image quality was assessed by two radiologists.Volume CT dose index(CTDIVOI)and dose length product(DLP)were compared as well.Results:Statistical differences were observed between P1 and P2 groups in intravascular CT values,SNR,and CNR at the aorta,external iliac artery,popliteal artery,and anterior tibial artery.No statistically significant difference was seen in intravascular CT values,SNR,or CNR at the femoral artery.The mean intravascular CT value in the P2 group was higher than that in the P1 group((534.4±25.2)vs.(480.6±143.4)),and showed better consistency in each part.In the subjective evaluation,significant differences were found in image quality scores for the aorta and inferior knee arteries between P1 and P2 groups,but no significant differences between groups were found in image quality scores for the femoral artery and popliteal artery The radiation dose in the P2 group was significantly lower than that in the P1 group,including a 64.0%reduction in CTDIvol((0.9±0.3)mGy to(0.5±0.3)mGy)and a 63.4%reduction in DLP((113.5±33.4)mGy·cm to(310.1±53.5)mGy·cm).Conclusion:Lower extremity CTA combined with dual-source CT caudo-cranial Flash scanning yields better quality images in the small arterial system below the knee with higher CT values,SNR,and CNR,and better consistency than single-source CT cranio-cauda scanning.This method also reduces the radiation dose for lower extremity CTA examinations.关键词
下肢动脉CTA/足头向/头足向/辐射剂量/图像质量Key words
lower extremity computed tomography angiography/cranio-cauda/caudo-cranial/radiation dose/image quality分类
医药卫生引用本文复制引用
戚荣飞,姜文龙,郝芸芸,杨柳莎,常英娟,吴志斌..足头向Flash扫描对下肢动脉CTA图像质量和辐射剂量的研究[J].CT理论与应用研究,2025,34(3):385-391,7.